A normal diode that is a non defective diode will read anywhere from 50 000 to 200 000 ohms.
What does a microwave diode look like.
During negative half cycle diode is out of picture.
According to edison tech center the cavity magnetron is the central part of a microwave the concept of the magnetron was invented in the 30s by dr.
This diode is rated for thousands of volts which is what the magnetron circuitry produces.
How to diagnose microwave not cooking issues.
Some of them may look alike on the outside but their internal characteristics may not be the same.
It is not many diodes in series as you suggest.
The parallel resistance cross capacitor is bleeder resistor.
During positive half cycle capacitor charges to the peak of the secondary voltage.
Unplug your microwave before beginning this inspection.
This could be caused by a problem with the high voltage diode which helps to power the magnetron.
Hull in schenectady new york.
How to test a microwave high voltage diode with a multimeter.
The power flows from the end without the stripe to the end with the stripe.
Which looks like a circle on the end of the wire.
The positive side won t have a band and will have a bit that goes to the capacitor.
Locate and remove your high voltage diode to test it for continuity.
Reverse the meter probes and measure resistance while touching the positive probe to the cathode and the negative probe to the anode.
We have manuals guides and of course parts for common ms19m8000as aa 0000 problems.
Differences in microwave make and model account for this large range in resistance readings.
The magnetron operates as an oscillator which is a device that generates oscillatory electric currents or voltages by nonmechanical means.
Pretty much like a fuse.
Look for the marking a colored stripe on the diode or resistor that indicates which way the current flows.
Your microwave may turn on but not heat up.
Testing the diode is done just like any lower voltage diode infinite resistance in one direction low resistance when you reverse the ohmmeter test leads less than 10 ohms.
The negative side is the cathode side and the positive side is the anode side.